WIKA O-10(T) O-10(5)
通用型压力变送器 用于液压气压泵压缩机
OEM pressure transmitter for general industrial applications
Models O-10 (T), O-10 (5)
Pressure transmitter model O-10 (T)
Applications
Hydraulics and pneumatics
Pumps and compressors
Machine building
Building services
Special features
Measuring ranges from 0 … 6 to 0 … 600 bar
Non-linearity 0.5 %
Standard industrial signals
Electrical connection: Angular connector form A and C,
circular connector M12 x 1, Metri-Pack series 150,
cable outlet 2 m unshielded or shielded
Many internationally customary process connections
Description
The model O-10 pressure transmitter has been developed for a wide variety of industrial applications. The large range of process and electrical connections as well as all commonly used pressure ranges and output signals set the model O-10
apart.
For applications in which water is used as a medium we recommend a 5-fold overpressure safety in combination with a condensation-tight case.
Due to its specifications, its features and its price, the pressure transmitter is ideally suited to OEM applications, with an annual quantity requirement of more than 1,000 units of each article number. Accordingly, the minimum order quantity is 50 units per article number.
The model O-10 has been designed specifically for the demands of the global market. The pressure transmitter offers international units and the corresponding approvals for the North American and Russian markets.
It goes without saying that the model O-10 can be delivered with customer-specific labelling (e.g. company logo and model designation).
Versions
Model O-10 (T)
Standard version
Model O-10 (5)
With 5-fold overpressure limit and condensation-tight case
For applications with water as a medium we recommend a 5-fold overpressure safety for protection against water hammer
effects, and a condensation-tight case.
Measuring ranges
Model O-10 (T)
Output signals
Model O-10 (T)
Voltage supply
Power supply
The power supply depends on the selected output signal.
4 ... 20 mA: DC 8 ... 30 V
DC 0.5 ... 4.5 V: DC 8 ... 30 V
DC 0 ... 5 V: DC 8 ... 30 V
DC 1 ... 5 V: DC 8 ... 30 V
DC 0 ... 10 V: DC 14 ... 30 V
DC 0.5 ... 4.5 V (ratiometric): DC 4.5 ... 5 V
The power supply for the pressure transmitter must be made via an energy-limited electrical circuit in accordance with section 9.4 of UL/EN/IEC 61010-1, or an LPS to UL/EN/IEC 60950-1, or class 2 in accordance with UL1310/UL1585 (NEC or CEC).
The power supply must be suitable for operation above 2,000 m should the pressure transmitter be used at this altitude.
Total current consumption
Current output:
The total current consumption corresponds to the value of the output signal current (4 ... 20 mA), maximum 25 mA
Voltage output:
5 mA
Reference conditions (per IEC 61298-1)
Temperature
15 ... 25 °C
Atmospheric pressure
860 ... 1,060 mbar
Humidity
45 ... 75 % relative
Power supply
Current output: DC 14 V
Voltage output: DC 24 V
Ratiometric output signal: DC 5 V
Nominal position
Calibrated in vertical mounting position with pressure connection facing downwards.
Time response
Settling time
< 2 ms
Accuracy data
Model O-10 (T)
Non-linearity (per IEC 61298-2)
≤ ±0.5 % of span BFSL
A different non-linearity applies to some measuring ranges, see "Measuring ranges O-10 (T)".
Measuring deviation of the zero signal
≤ ±0.5 % of span
A different measuring deviation applies to some measuring ranges, see "Measuring ranges model O-10 (T)".
Accuracy at reference conditions
≤ ±1.2 % of span
Temperature error at 0 ... 80 °C
≤ ±1.5 % of span
Long-term stability
≤ ±0.3 % of span/year
Model O-10 (5)
Non-linearity (per IEC 61298-2)
≤ ±0.5 % of span BFSL
Measuring deviation of the zero signal
≤ ±1 % of span
Accuracy at reference conditions
≤ ±2.0 % of span
Temperature error at 0 ... 80 °C
Mean temperature coefficient of zero point:
Typical: 0.3 % of span/10 K
Maximum: 0.6 % of span/10 K
Mean temperature coefficient of span:
≤ ±0.1 % of span/10 K
Long-term drift
≤ ±0.8 % of span/year
Operating conditions
Model O-10 (T)
Ingress protection (per IEC 60529)
For ingress protections see "Electrical connections model O-10 (T)"
The stated ingress protection only applies when plugged in using mating connectors that have the appropriate ingress protection.
Vibration resistance (per IEC 60068-2-6)
20 g (20 ... 2,000 Hz, 120 min.)
Shock resistance (per IEC 60068-2-27)
40 g (6 ms), mechanical shock
欢迎致电咨询订购WIKA O-10(T) O-10(5) 通用型压力变送器 用于液压气压泵压缩机
电话:010-51669912 56291930 15910733293
传真:010-51669912
QQ:823377546 1491421115 2636968574
邮箱:sales@zoriver.cn
公司官网:http://www.zoriver.cn http://www.zoriver.com.cn
卓尔瑞华(北京)科技有限公司
联系人:仇立新 先生 (销售工程师)
电 话:010-56291930
传 真:010-51669912
手 机:15910733293
地 址:中国北京丰台区北京市丰台区成寿寺路关家坑206号
邮 编:100078
网 址:
http://zoriver.qy6.com.cn(
加入收藏)